Inspection Criteria
- Strands to be visible through the inspection hole
- Strands not to be visible between the insulation and barrel
- Crimped contact to meet recommended conductor tensile
force shown in chart (see reference PDF)
- Check for peeled gold and bent contacts
Correctly Crimped Contact
Cross Section of Correctly Crimped Contact
Examples of Crimping Faults
Pull Testing
Using the correct wire gauge and
crimp tooling for a particular contact will help ensure customers maximize the electrical and mechanical integrity of their crimps. Positronic recommends performing frequent pull tests on the crimped contacts. Please refer to the Positronic Recommended
Conductor Tensile Strength chart (see reference PDF) as a starting point
for identifying acceptable tensile values.
Positronic Recommended Conductor Tensile Strength
- See reference PDF for chart of recommended conductor tensile strength