Power Connection Systems

Technical Specifications: Safety Shroud

 

UL Recognized: File# E49351
CSA Recognized: File# LR54219
TUV Recognized: File# 13/97

Materials and Finishes
Insulator: Glass-filled polyester, UL 94V-0. Contact technical sales for availability of high temperature insulator material.
Contacts: Precision machined copper alloy. Solder coated terminations optional.

Standard Finish: Gold flash over nickel

Optional Finishes:
0.000030 inch (0.76 µ) gold over nickel
0.000050 inch (1.27 µ) gold over nickel
Push-on Fastener: Spring tempered copper alloy, tin plate.
Electrical Characteristics
Contact Current Rating: 40 amperes continuous, derated per IEC 512-3, test 5b. Higher currents available with high conductivity contacts, contact Technical Sales.
Initial Contact Resistance: 0.001 ohms max. per IEC 512-2, test 2b.
Insulation Resistance: 5 G ohms per IEC 512-2, test 3a.
Voltage Proof: 3,000 minimum V r.m.s. per IEC 512-2, test 4a, method A.
Clearance and Creepage Distance: 0.220 [5.60] minimum
Working Voltage: 600 minimum V. r.m.s.
Hot Pluggable [50 couplings per UL 1977 paragraph 15]: 250 VAC at 20 amperes
Working Temperature: -55°C to +125°C Contact technical sales for availability of high temperature insulator
Mechanical Characteristics
Removable Contacts: Rear insertion/ front release. Female contact features "Closed Entry" design for highest reliability. 0.094 [2.39] diameter male contact.
Removable Contact Retention in Insulator: 15 lbs. [67N] per IEC 512-8, test 15a.
Fixed Contacts: Printed board terminations, both straight and 90°. Female contact features "Closed Entry" design for highest reliability. 0.094 [2.39] diameter male contact.
Fixed Contact Retention in Insulator: 15 lbs. [67N], minimum.
Resistance to Soldering Iron Heat: 500°F [260°C] for 10 seconds duration per IEC 512-6, test 12e, 25 watt soldering iron.
Contact Terminations: Crimp removable contacts for wire size 12 AWG [4.0 mm²]. Straight and 90° solder printed board mount, 0.090 [2.29] tail diameter.
Connection Systems: Cable to cable, cable to printed board and cable to panel mount.
Locking System: Insulators provide locking between cable to cable, cable to printed board and cable to panel mount applications.
Polarization: Provided in insulator design.
Mounting to PC Board: Rapid installation push-on fasteners.
Mechanical Operations: 500 operations
Power Connection Systems