Circle Hex

Technical Specifications

 
Materials and Finishes
Insulator: GH/MGH Series: Glass-filled DAP per ASTM-D-5948, Type SGD-F. Grey color is standard.

LGH Series: Glass-filled polyester per MIL-M-24519, UL 94V-0. Grey color.
Contacts: Precision machined copper alloy
Contact Plating: Gold flash over nickel.
Hoods: GH/MGH Series: Aluminum with yellow or black anodize.

GH Series: Glass-filled DAP.
Lock Rings and Lock Springs: Copper alloy with zinc plate and chromate seal.
Mechanical Characteristics
Fixed Contacts:
Male: GH/LGH Series: Size 20. 0.040 inch [1.02 mm] mating diameter.

MGH Series: Two size 22, 0.030 inch [0.76 mm] mating diameter. One size 20, 0.040 inch [1.02 mm] mating diameter.
Female: GH Series: Open entry is standard. Closed entry is available on solder cup contacts for high reliability applications.

LGH Series: Open entry or closed entry design available.

MGH Series: Open entry.
 
Contact Retention in Insulator: GH Series: 10 lbs. [44.5 N], minimum.

LGH Series: 9 lbs. [40 N]

MGH Series: 6 lbs. [26.5 N], minimum.
 
Contact Terminations:
Solder cup contacts: GH/LGH Series: 0.046 inch [1.17 mm] hole diameter for 20 AWG [0.5 mm²] wire maximum.

MGH Series: 0.027 inch [0.69 mm] hole diameter for 24 AWG [0.25 mm²] wire maximum.
Straight printed board mount: GH Series: 0.025 inch [0.64 mm] termination diameter.

LGH Series: 0.030 inch [0.76 mm] termination diameter.
 
Locking Systems: MGH Series: Friction, lock spring with lock ring.
Polarization: GH Series: 0.056 inch [1.42 mm] diameter male contact in position "A" on Size 4 connector. Molding configuration provides polarization on other sizes.

LGH Series: Center post provides polarization of connector.

MGH Series: 0.040 inch [1.02 mm] diameter male contact in position "A".
Mechanical Operations: Open entry contacts: 250 operations per IEC 60512-5.

Closed entry contacts: 500 operations per IEC 60512-5.
Electrical Characteristics
Contact Current Rating: GH/LGH Series: 7.5 amperes, maximum.

MGH Series: 5 amperes.
Initial Contact Resistance: GH Series: 0.010 ohms, maximum.

LGH Series: 0.008 ohms, maximum.

MGH Series: 0.012 ohms, maximum.
Flash over Voltage: GH Series: 1,750 VAC (rms).

MGH Series: 1,500 VAC (rms).
Test Voltage: GH Series: 1,200 VAC (rms).

MGH Series: 1,000 VAC (rms).
Insulation Resistance: GH/MGH Series: 5 G ohms
Clearance and Creepage Distance: GH Series: 0.025 inch [0.64 mm], minimum.

LGH Series: 0.039 inch [1.0 mm], minimum.

MGH Series: 0.021 inch [0.53 mm], minimum.
Working Voltage: 600 VAC (rms).
Climatic Characteristics
Temperature Range: -55°C to +125°C
Damp Heat, Steady State: GH/MGH Series: 21 days.

LGH Series: 10 days.
Circle Hex