Materials and Finishes
Insulator: Glass filled polyester per ASTM D5927, UL 94V-0, blue color.
Contacts: Precision machined copper alloy.
Contact Plating: Professional performance - gold flash over nickel plate. Other finishes available upon request.
Shells: Steel with tin plate; zinc plate with chromate seal, stainless steel passivated. Other materials and finishes available upon request.
Mounting Spacers and Brackets: Copper alloy or steel with zinc plate and chromate seal or tin plate; stainless steel, passivated.
Jackscrew Systems: Brass or steel with zinc plate and chromate seal or clear zinc plate or tin plate; stainless steel, passivated.
Vibration Lock Systems: Slide lock and lock tabs, steel with nickel plate
Low magnetic versions are available. Contact Technical Sales.
 
Environmental Initiatives
Mechanical Characteristics
Contacts
Solid Metal Construction:
Male: PCD: Size 20. 0.040 inch [1.02 mm] mating diameter.

PCDD: Size 22. 0.030 inch [0.76 mm] mating diameter.
Female: PCD: Size 20.

PCDD: Size 22.

Rugged open entry design or PosiBand closed entry design.
 
Contact retention in insulator: 5 lbs. [21 N] minimum.
Connector Polarization: Trapezoidal shaped shells and polarized jackscrews.
Locking system: Jackscrews and vibration locking systems.
Mechanical Operations: Open entry contacts: 500 operations minimum

PosiBand closed entry contacts: 1000 operations minimum

Per IEC 60512-5
Electrical Characteristics:
Contact Current Rating:
Open entry contacts: PCD: 7.5 amperes nominal

PCDD: 5 amperes nominal
PosiBand closed entry contacts, tested per UL 1977

PCD Series:
18 amperes, 2 contacts energized.

14 amperes, 6 contacts energized.

11 amperes, 15 contacts energized.

10 amperes, 25 contacts energized.

9 amperes, 50 contacts energized.
PosiBand closed entry contacts, tested per UL 1977

PCDD Series:
12 amperes, 2 contacts energized.

10 amperes, 6 contacts energized.

7.5 amperes, 26 contacts energized.

6.5 amperes, 65 contacts energized.

5.0 amperes, 104 contacts energized.
See Temperature Rise Curves for details.
 
Initial Contact Resistance:
Open entry contacts: PCD: 0.008 ohms maximum.

PCDD: 0.010 ohms maximum.

Per IEC 60512-2, Test 2a.
PosiBand closed entry contacts 0.005 ohms maximum.
 
Proof Voltage: 1000 V r.m.s.
Insulation Resistance: 5 G ohms
Clearance and Creepage Distance (minimum): PCD: 0.039 inch [1.00 mm]

PCDD: 0.042 inch [1.02 mm]
Working Voltage: 300 V
Electrical Characteristics of Compliant Connection to Plated-Through-Hole of PCB
Initial Contact Resistance of Connection: Less than 0.001 ohms per IEC 60512-2, Test 2a.
Change in Contact Resistance of Connection after Mechanical, Electrical, Or Climatic Conditioning: Less than 0.001 ohms increase per IEC 60512-2, Test 2a.
Gas-tight Connections Test: Less than 0.001 ohms increase in contact resistance after 1 hour per EIA 364, TP36, Method One.
Climatic Characteristics
Temperature Range: -55°C to +125°C